Vacuum Interrupter 1.14KV 160A HCJ5 for vacuum contactor from jucro electric
YICHANG TOP IMP.&EXP. CO., LTD.
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

Vacuum Interrupter 1.14KV 160A HCJ5 for vacuum contactor from jucro electric
YICHANG TOP IMP.&EXP. CO., LTD.The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Size: 15*32
- Color: white
- Structure: Other
- Arc-extinguishing medium: Other
- Poles number: 3
- Installation: Insert
- Exports to: Russia, Other European Countries, Japan and South Korea
About this product
- Size: 15*32
- Color: white
- Structure: Other
- Arc-extinguishing medium: Other
- Poles number: 3
- Installation: Insert
- Exports to: Russia, Other European Countries, Japan and South Korea
Product details
| Size | 15*32 |
|---|---|
| Color | white |
| Structure | Other |
| Arc-extinguishing medium | Other |
| Poles number | 3 |
| Installation | Insert |
| Certification | CEOther |
Product details
| Size | 15*32 |
|---|---|
| Color | white |
| Structure | Other |
| Arc-extinguishing medium | Other |
| Poles number | 3 |
| Installation | Insert |
| Certification | CEOther |
From the supplier
Vacuum Inteerrupter HCJ5-1.14KV 125A for vacuum contaCTor from JUCRO Electric
Brief introduction
The Vacuum Interrupter interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environment
Vacuum Tube main technique parameter
No.
Parameter name
Unit
Value
1
Rated voltage
kV
1.14
2
Rated current
A
160
3
Rated frequency
Hz
50
4
Rated making current
A
1600
5
Rated breaking current
A
1280
6
Limiting breaking current
A
1600
7
Rated short-time withstand current
A
1280
8
Rated short-time withstand voltage
kV
10
9
Mechanical life
times
1000000
10
Breaking operations
AC3
times
150000
AC4
6000
11
Automatic closing force of the contacts
N
25±10
12
Force required to hold contacts open at full stork
N
40±10
13
Circuit resistance at lowest rated contacts force
μΩ
≤120
14
Limiting abrasion of contacts
mm
2
15
Storage life
year
20
16
Internal gas pressure
Pa
≤1.33×10-3
From the supplier
Vacuum Inteerrupter HCJ5-1.14KV 125A for vacuum contaCTor from JUCRO Electric
Brief introduction
The Vacuum Interrupter interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environment
Vacuum Tube main technique parameter
No.
Parameter name
Unit
Value
1
Rated voltage
kV
1.14
2
Rated current
A
160
3
Rated frequency
Hz
50
4
Rated making current
A
1600
5
Rated breaking current
A
1280
6
Limiting breaking current
A
1600
7
Rated short-time withstand current
A
1280
8
Rated short-time withstand voltage
kV
10
9
Mechanical life
times
1000000
10
Breaking operations
AC3
times
150000
AC4
6000
11
Automatic closing force of the contacts
N
25±10
12
Force required to hold contacts open at full stork
N
40±10
13
Circuit resistance at lowest rated contacts force
μΩ
≤120
14
Limiting abrasion of contacts
mm
2
15
Storage life
year
20
16
Internal gas pressure
Pa
≤1.33×10-3
About the supplier
- ✓Exhibited at 4 recent Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2011
Light & Electrical exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 4 recent Canton Fairs
- Foreign Trade Company
- Founded 2011