Medium voltage cable
Zhengzhou Jinhang High-tech CO.,LTD
See what’s includedHide breakdown
- FOB goods (500)
- $4,125
- Ocean freight + handling (1.5 CBM)
- $880
- US duty (2.7%)
- $111
- Section 301 tariff (25.0%)
- $1,031
- Customs fees (MPF/HMF)
- $38
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from your agent uses real carton sizes, freight and the exact tariff line.
- FOB goods (500)
- $4,125
- Ocean freight + handling (1.5 CBM)
- $880
- US duty (2.7%)
- $111
- Section 301 tariff (25.0%)
- $1,031
- Customs fees (MPF/HMF)
- $38
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from your agent uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

Medium voltage cable
Zhengzhou Jinhang High-tech CO.,LTDSee what’s includedHide breakdown
- FOB goods (500)
- $4,125
- Ocean freight + handling (1.5 CBM)
- $880
- US duty (2.7%)
- $111
- Section 301 tariff (25.0%)
- $1,031
- Customs fees (MPF/HMF)
- $38
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from your agent uses real carton sizes, freight and the exact tariff line.
- FOB goods (500)
- $4,125
- Ocean freight + handling (1.5 CBM)
- $880
- US duty (2.7%)
- $111
- Section 301 tariff (25.0%)
- $1,031
- Customs fees (MPF/HMF)
- $38
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from your agent uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Materials: aluminum or copper
- Size: 35-1000mm2
- Color: black, red, gray, etc.
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, EU, Other European Countries, Others
- Made in: Henan, China
About this product
- Materials: aluminum or copper
- Size: 35-1000mm2
- Color: black, red, gray, etc.
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, EU, Other European Countries, Others
- Made in: Henan, China
Product details
| Materials | aluminum or copper |
|---|---|
| Size | 35-1000mm2 |
| Color | black, red, gray, etc. |
Product details
| Materials | aluminum or copper |
|---|---|
| Size | 35-1000mm2 |
| Color | black, red, gray, etc. |
From the supplier
Applications
cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Construction
Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over an aluminum or cooper conductor and cured in a single operation. Uncoated copper tape (helically applied) and overlaying black PVC jacket are applied over the cable core. The conductor Class B compressed concentric lay filled. Conductor shield is an extruded semi-conducting thermosetting polymeric stress control layer. Insulation is extruded XLPE. Insulation shield is an extruded semi-conducting thermosetting layer, clean and free-stripping from insulation. The metallic shield is flat uncoated 5-mil-thick copper tape helically applied with minimum 25% overlap. The jacket is sunlight and moisture resistant black, non-conducting PVC (Polyvinyl Chloride)
Features
Triple-extruded for clean interfaces
Dry nitrogen cure for enhanced performance
Class 10,000 environment utilized for material handling
Excellent moisture resistance
High dielectric strength
Low dielectric loss
Excellent resistance to treeing
Clean-stripping insulation shield
Sunlight and Moisture Resistant
Approved for CT use 1/0 and Larger
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-93-639 5-46KV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Temperature Rating
Normal ..............90 ºC
Emergency........130 ºC
Short Circuit........250 ºC
Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.
Options
Copper conductors
CPE (chlorinated polyethylene) Jacket conforming to the requirements specified for chlorinated polyethylene jackets in ICEA. The average thickness shall be in accordance with Table 4-3 of ICEA and the minimum spot thickness shall be not less than 80% of the average thickness
Non-filled conductor
Compact Strand ConductorFor information on conductor sizes or voltage ratings not shown in the tables, contact your AWG sales representative.
Notes
Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8.
Ampacity based on earth thermal resistivity of 90ºC-cm/watt, 105ºC conductor temp., 20ºC earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass
From the supplier
Applications
cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Construction
Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over an aluminum or cooper conductor and cured in a single operation. Uncoated copper tape (helically applied) and overlaying black PVC jacket are applied over the cable core. The conductor Class B compressed concentric lay filled. Conductor shield is an extruded semi-conducting thermosetting polymeric stress control layer. Insulation is extruded XLPE. Insulation shield is an extruded semi-conducting thermosetting layer, clean and free-stripping from insulation. The metallic shield is flat uncoated 5-mil-thick copper tape helically applied with minimum 25% overlap. The jacket is sunlight and moisture resistant black, non-conducting PVC (Polyvinyl Chloride)
Features
Triple-extruded for clean interfaces
Dry nitrogen cure for enhanced performance
Class 10,000 environment utilized for material handling
Excellent moisture resistance
High dielectric strength
Low dielectric loss
Excellent resistance to treeing
Clean-stripping insulation shield
Sunlight and Moisture Resistant
Approved for CT use 1/0 and Larger
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-93-639 5-46KV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Temperature Rating
Normal ..............90 ºC
Emergency........130 ºC
Short Circuit........250 ºC
Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.
Options
Copper conductors
CPE (chlorinated polyethylene) Jacket conforming to the requirements specified for chlorinated polyethylene jackets in ICEA. The average thickness shall be in accordance with Table 4-3 of ICEA and the minimum spot thickness shall be not less than 80% of the average thickness
Non-filled conductor
Compact Strand ConductorFor information on conductor sizes or voltage ratings not shown in the tables, contact your AWG sales representative.
Notes
Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8.
Ampacity based on earth thermal resistivity of 90ºC-cm/watt, 105ºC conductor temp., 20ºC earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass
About the supplier
Main products: Wires,Cables,Household cable,Coaxial cable
- ✓Exhibited at 10 of the last 10 Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2007
Light & Electrical exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 10 of the last 10 Canton Fairs
- Foreign Trade Company
- Founded 2007