
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Size: 30-50cm
- Color: silver
- Brand: Other
- Application: Overhead
- Rangeof application: Other
- Certification: ISO9001
- Exports to: Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries
About this product
- Size: 30-50cm
- Color: silver
- Brand: Other
- Application: Overhead
- Rangeof application: Other
- Certification: ISO9001
- Exports to: Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries
Product details
| Size | 30-50cm |
|---|---|
| Color | silver |
| Brand | Other |
| Application | Overhead |
| Rangeof application | Other |
| Certification | ISO9001 |
| Insulation material | Other |
| Conductor material | Aluminum |
| Sheath material | Other |
| Material shape | RoundWire |
| Conductor type | Solid |
Product details
| Size | 30-50cm |
|---|---|
| Color | silver |
| Brand | Other |
| Application | Overhead |
| Rangeof application | Other |
| Certification | ISO9001 |
| Insulation material | Other |
| Conductor material | Aluminum |
| Sheath material | Other |
| Material shape | RoundWire |
| Conductor type | Solid |
From the supplier
Overhead Bare Aluminium ACSR Conductor for ASTM BS IEC Standards
1.Applications of Overhead ACSR wire
Aluminum Conductors Steel Reinforced (ACSR) consists of a galvanized steel core of 1 wire,7 wires or 19 wires surrounded by concentric layers of aluminum wire, when a conductor with a high current carrying capacity and comparatively low strength is required,special constructions are available with high aluminum content. It's used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design.Variable steel core stranding enables desired strength to be achieved without sacrificing capacity.
This catalogue shows the most common sizes of conductor but other sizes, to any recognized standards or customer specification can also be supplied. ACSR insulated with XLPE or PVC can also be supplied as per customer's requirements.
2.Specifications of ACSR Conductors
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
3.Notes of ACSR Cable
- · Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
- · Current ratings are based on 75 ºC conductor temperature, 25 ºC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.
From the supplier
Overhead Bare Aluminium ACSR Conductor for ASTM BS IEC Standards
1.Applications of Overhead ACSR wire
Aluminum Conductors Steel Reinforced (ACSR) consists of a galvanized steel core of 1 wire,7 wires or 19 wires surrounded by concentric layers of aluminum wire, when a conductor with a high current carrying capacity and comparatively low strength is required,special constructions are available with high aluminum content. It's used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design.Variable steel core stranding enables desired strength to be achieved without sacrificing capacity.
This catalogue shows the most common sizes of conductor but other sizes, to any recognized standards or customer specification can also be supplied. ACSR insulated with XLPE or PVC can also be supplied as per customer's requirements.
2.Specifications of ACSR Conductors
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
3.Notes of ACSR Cable
- · Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
- · Current ratings are based on 75 ºC conductor temperature, 25 ºC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.
About the supplier
Main products: Cables
- ✓Exhibited at 7 recent Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2007
- ✓Canton Fair Premium Supplier
- ✓Brand exhibitor
- ✓National high-tech enterprise
Light & Electrical exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 7 recent Canton Fairs
- Foreign Trade Company
- Founded 2007
- Canton Fair Premium Supplier