CJX9-3P 40A 24/120/208/240/277V air conditioning magnetic contactor
SHANGHAI CET ELECTRIC CO., LTDSee what’s includedHide breakdown
- FOB goods (100)
- $1,143
- Ocean freight + handling (0.30 CBM)
- $820
- US duty (2.7%)
- $31
- Section 301 tariff (25.0%)
- $286
- Customs fees (MPF/HMF)
- $34
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
- FOB goods (100)
- $1,143
- Ocean freight + handling (0.30 CBM)
- $820
- US duty (2.7%)
- $31
- Section 301 tariff (25.0%)
- $286
- Customs fees (MPF/HMF)
- $34
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
CJX9-3P 40A 24/120/208/240/277V air conditioning magnetic contactor
SHANGHAI CET ELECTRIC CO., LTDSee what’s includedHide breakdown
- FOB goods (100)
- $1,143
- Ocean freight + handling (0.30 CBM)
- $820
- US duty (2.7%)
- $31
- Section 301 tariff (25.0%)
- $286
- Customs fees (MPF/HMF)
- $34
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
- FOB goods (100)
- $1,143
- Ocean freight + handling (0.30 CBM)
- $820
- US duty (2.7%)
- $31
- Section 301 tariff (25.0%)
- $286
- Customs fees (MPF/HMF)
- $34
Estimate in USD to a US port using category averages (HTS 8536/8504/8507), rates as of 2026-09. Other countries on request. A quote from our desk uses real carton sizes, freight and the exact tariff line.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Materials: AL
- Color: Black
- Exports to: Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
- Made in: Zhejiang, China
About this product
- Materials: AL
- Color: Black
- Exports to: Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
- Made in: Zhejiang, China
Product details
| Materials | AL |
|---|---|
| Color | Black |
Product details
| Materials | AL |
|---|---|
| Color | Black |
From the supplier
This series contactor is mainly applicable to a line of AC 50Hz or 60Hz,rated working voltage up to 600V and rated working current up to 90A,used to close or and to switch off the line.It complines to IEC947-4-1 standard.
Why do air conditioners need special contactors
1. Under normal circumstances, the three-phase load current and the ground leakage current are basically balanced. The phasor sum of the primary coil current flowing through the transformer is about zero, that is, the total magnetic flux generated by it in the iron core is zero, and the zero sequence transformer No output from secondary coil.
2. When an electric shock occurs, the electric shock current forms a loop through the ground, that is, a zero sequence current is generated. This current does not flow back through the primary coil of the transformer, which breaks the balance, so there is zero-sequence magnetic flux in the iron core, which causes the secondary coil to output a signal. This signal is judged by the amplifying and comparing elements. If it reaches a predetermined action value, it will send an execution signal to the actuator to trip and cut off the power supply.
3. It can be seen from the working principle that when the impedance difference between the three relative grounds is large, the phasor of the three relative ground leakage currents and the action value of the protector will be reached, the circuit breaker will be tripped or not powered. At the same time, the phases of the three-phase leakage current and the electric shock current are inconsistent or reversed, which will reduce the sensitivity of the protector.
Model: CJX9-3P
Rated current:40A
Poles:3P
Coil voltage:24V;120V;208/240V;277V
Brand: SHCET or OEM
CJX9 Air Conditioning ContactorStandardIEC/EN 60947-4-1ProductAir Conditioning ContactorModel Full Load AmpsResistive Amps 600VACLocked Rotor Amps 240/277VACLocked Rotor Amps 480VACLocked Rotor Amps 600VACCoil Voltage1 Pole ContactorCJX9-1P20A301201008024V;120V;208/240V;277VCJX9-1P25A35125125100CJX9-1P30A40125125100CJX9-1P40A501601601202 Pole ContactorCJX9-2P20A301001008024V;120V;208/240V;277VCJX9-2P25A35125125100CJX9-2P30A40125125100CJX9-2P40A501601601203 Pole ContactorCJX9-3P20A301201008024V;120V;208/240V;277VCJX9-3P25A35150125100CJX9-3P30A40180150100CJX9-3P40A50240200120CJX9-3P50A44300250200CJX9-3P60A75360300240CJX9-3P75A90450375300CJX9-3P90A1205404503604 Pole ContactorCJX9-4P30A4018015012024V;120V;208/240V;277VCJX9-4P40A50240200160
From the supplier
This series contactor is mainly applicable to a line of AC 50Hz or 60Hz,rated working voltage up to 600V and rated working current up to 90A,used to close or and to switch off the line.It complines to IEC947-4-1 standard.
Why do air conditioners need special contactors
1. Under normal circumstances, the three-phase load current and the ground leakage current are basically balanced. The phasor sum of the primary coil current flowing through the transformer is about zero, that is, the total magnetic flux generated by it in the iron core is zero, and the zero sequence transformer No output from secondary coil.
2. When an electric shock occurs, the electric shock current forms a loop through the ground, that is, a zero sequence current is generated. This current does not flow back through the primary coil of the transformer, which breaks the balance, so there is zero-sequence magnetic flux in the iron core, which causes the secondary coil to output a signal. This signal is judged by the amplifying and comparing elements. If it reaches a predetermined action value, it will send an execution signal to the actuator to trip and cut off the power supply.
3. It can be seen from the working principle that when the impedance difference between the three relative grounds is large, the phasor of the three relative ground leakage currents and the action value of the protector will be reached, the circuit breaker will be tripped or not powered. At the same time, the phases of the three-phase leakage current and the electric shock current are inconsistent or reversed, which will reduce the sensitivity of the protector.
Model: CJX9-3P
Rated current:40A
Poles:3P
Coil voltage:24V;120V;208/240V;277V
Brand: SHCET or OEM
CJX9 Air Conditioning ContactorStandardIEC/EN 60947-4-1ProductAir Conditioning ContactorModel Full Load AmpsResistive Amps 600VACLocked Rotor Amps 240/277VACLocked Rotor Amps 480VACLocked Rotor Amps 600VACCoil Voltage1 Pole ContactorCJX9-1P20A301201008024V;120V;208/240V;277VCJX9-1P25A35125125100CJX9-1P30A40125125100CJX9-1P40A501601601202 Pole ContactorCJX9-2P20A301001008024V;120V;208/240V;277VCJX9-2P25A35125125100CJX9-2P30A40125125100CJX9-2P40A501601601203 Pole ContactorCJX9-3P20A301201008024V;120V;208/240V;277VCJX9-3P25A35150125100CJX9-3P30A40180150100CJX9-3P40A50240200120CJX9-3P50A44300250200CJX9-3P60A75360300240CJX9-3P75A90450375300CJX9-3P90A1205404503604 Pole ContactorCJX9-4P30A4018015012024V;120V;208/240V;277VCJX9-4P40A50240200160
About the supplier
Main products: Road illumination fittings,Projection light,High bay,Small breaker ( low-voltage apparatus),Electric meter
- ✓Exhibited at 10 of the last 10 Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2007
Light & Electrical exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 10 of the last 10 Canton Fairs
- Foreign Trade Company
- Founded 2007











