Two cores aerial bundled cable insulated
Zhengzhou Jinshui Industry and Commerce Co.,Ltd.
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if unreachable

Two cores aerial bundled cable insulated
Zhengzhou Jinshui Industry and Commerce Co.,Ltd.The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if unreachable
About this product
- Materials: AAC /XLPE insulation AAAC/XLPE insulation
- Size: 3*70mm2
- Color: black
- Exports to: Middle East, Southeast Asia, South Asia, Latin America
- Made in: Henan, China
About this product
- Materials: AAC /XLPE insulation AAAC/XLPE insulation
- Size: 3*70mm2
- Color: black
- Exports to: Middle East, Southeast Asia, South Asia, Latin America
- Made in: Henan, China
Product details
| Materials | AAC /XLPE insulation AAAC/XLPE insulation |
|---|---|
| Size | 3*70mm2 |
| Color | black |
Product details
| Materials | AAC /XLPE insulation AAAC/XLPE insulation |
|---|---|
| Size | 3*70mm2 |
| Color | black |
From the supplier
Application
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentric strand or compressed 1350-H19 conductor,polyethylene or crosslinked polyethylene insulation, concentric strand AAC,ACSR,or 6201 alloy neutral messenger.
Standards
ASTM B-230,B-231,B-232 and B-399
ICEA S-76-474
The Diagram of Structure
NOTE:Designated Sizes are ACSR 6/1 Diameter Equivalent Resistivity Per ASTM-B-399 for 6201.
Conductor temperature of 75oC;ambient temperatures of 40 oC;emissivity 0.9;2ft/sec.wind in sun.Packaging:Available in 500ft coils and in long lengths on reels.
The data is approximate and subject to normal manufacturing tolerances.
To determine current ampacity by conductor size,please consult The National Electric Code,latest edition.
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft(lbs)
Rating(Amps)
Size AWG
Strand
Insulation Thickness
(mls)
Size AWG
Strand
Breaking Strength
(lbs)
XLPE
POLY
XLPE
POLY
AAC
Pekingese
6
Solid
45
6
7/w
563
63.5
61.7
70
70
Collie
6
7/w
45
6
7/w
563
66.8
63.1
70
70
Dachshund
4
Solid
45
4
7/w
881
95.5
93.4
90
90
Spaniel
4
7/w
45
4
7/w
881
100.5
95.4
90
90
Doberman
2
7/w
45
2
7/w
1,350
152.7
145.7
120
120
Malemute
1/0
19/w
60
1/0
7/w
1,990
242.6
234.2
160
160
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft(lbs)
Rating(Amps)
Size AWG
Strand
Insulation Thickness
(mls)
Size AWG
Strand
Breaking Strength
(lbs)
XLPE
POLY
XLPE
POLY
ACSR NEUTRAL-MESSENGER
Setter
6
Solid
45
6
6/1
1,190
75.0
73.2
70
70
Shepherd
6
7/w
45
6
6/1
1,190
78.3
74.6
70
70
Eskimo
4
Solid
45
4
6/1
1,860
113.7
111.6
90
90
Terrier
4
7/w
45
4
6/1
1,860
118.7
113.6
90
90
Chow
2
7/w
45
2
6/1
2,850
181.7
174.7
120
120
Bull
1/0
19/w
60
1/0
6/1
4,380
288.7
280.3
160
160
6201 ALLOY NEUTRAL-MESSENGER
Chihuaha
6
Solid
45
6
7/w
1,110
67.6
65.8
70
70
Vizsla
6
7/w
45
6
7/w
1,110
70.9
67.2
70
70
Harrier
4
Solid
45
4
7/w
1,760
102.0
99.9
90
90
Whippet
4
7/w
45
4
7/w
1760
107.0
101.9
90
90
Schnauzer
2
7/w
45
2
7/w
2,800
163.3
156.2
120
120
Heeler
1/0
19/w
60
1/0
7/w
4,460
259.2
250.8
160
160
From the supplier
Application
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentric strand or compressed 1350-H19 conductor,polyethylene or crosslinked polyethylene insulation, concentric strand AAC,ACSR,or 6201 alloy neutral messenger.
Standards
ASTM B-230,B-231,B-232 and B-399
ICEA S-76-474
The Diagram of Structure
NOTE:Designated Sizes are ACSR 6/1 Diameter Equivalent Resistivity Per ASTM-B-399 for 6201.
Conductor temperature of 75oC;ambient temperatures of 40 oC;emissivity 0.9;2ft/sec.wind in sun.Packaging:Available in 500ft coils and in long lengths on reels.
The data is approximate and subject to normal manufacturing tolerances.
To determine current ampacity by conductor size,please consult The National Electric Code,latest edition.
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft(lbs)
Rating(Amps)
Size AWG
Strand
Insulation Thickness
(mls)
Size AWG
Strand
Breaking Strength
(lbs)
XLPE
POLY
XLPE
POLY
AAC
Pekingese
6
Solid
45
6
7/w
563
63.5
61.7
70
70
Collie
6
7/w
45
6
7/w
563
66.8
63.1
70
70
Dachshund
4
Solid
45
4
7/w
881
95.5
93.4
90
90
Spaniel
4
7/w
45
4
7/w
881
100.5
95.4
90
90
Doberman
2
7/w
45
2
7/w
1,350
152.7
145.7
120
120
Malemute
1/0
19/w
60
1/0
7/w
1,990
242.6
234.2
160
160
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft(lbs)
Rating(Amps)
Size AWG
Strand
Insulation Thickness
(mls)
Size AWG
Strand
Breaking Strength
(lbs)
XLPE
POLY
XLPE
POLY
ACSR NEUTRAL-MESSENGER
Setter
6
Solid
45
6
6/1
1,190
75.0
73.2
70
70
Shepherd
6
7/w
45
6
6/1
1,190
78.3
74.6
70
70
Eskimo
4
Solid
45
4
6/1
1,860
113.7
111.6
90
90
Terrier
4
7/w
45
4
6/1
1,860
118.7
113.6
90
90
Chow
2
7/w
45
2
6/1
2,850
181.7
174.7
120
120
Bull
1/0
19/w
60
1/0
6/1
4,380
288.7
280.3
160
160
6201 ALLOY NEUTRAL-MESSENGER
Chihuaha
6
Solid
45
6
7/w
1,110
67.6
65.8
70
70
Vizsla
6
7/w
45
6
7/w
1,110
70.9
67.2
70
70
Harrier
4
Solid
45
4
7/w
1,760
102.0
99.9
90
90
Whippet
4
7/w
45
4
7/w
1760
107.0
101.9
90
90
Schnauzer
2
7/w
45
2
7/w
2,800
163.3
156.2
120
120
Heeler
1/0
19/w
60
1/0
7/w
4,460
259.2
250.8
160
160
About the supplier
Main products: Cable
- ✓Exhibited at 10 of the last 10 Canton Fairs
- ✓Foreign Trade Company
- ✓Founded 2001
- ✓1 certificate on file
- Exhibited at 10 of the last 10 Canton Fairs
- Foreign Trade Company
- Founded 2001
- 1 certificate on file