RO Membrane
Jialong Technology ((Shenzhen) Co., Ltd.
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if unreachable

RO Membrane
Jialong Technology ((Shenzhen) Co., Ltd.The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if unreachable
From the supplier
TW-3012-600
- TestingCondition and Performance
Model
Pressure
psi(bar)
Permeate Flow
GPD(L/H)
Stable Rejection
(%)
TW-3012-600
100(6.9)
600(94.64)
96
- The flow and rejection are based on following testing condition: 500ppm softened tap water、temperature 25°C、pH7.5-8、recovery rate 35%and above testing pressure
- The minimum rejection is 95.0%。
- One single membrane flow may fluctuate within±20%
- Membrane Size
Model
inch(mm)
A
B
C
D
E
TW-3012-600
11.74
(298)
0.875
(21±0.5)
0.68
(17)
2.91
(74±1)
10
(254)
- 3.Operation Limits and Condition
Operation Limits
Membrane type
Polyamide composite membrane
Maximum feed water temperature
45℃
Maximum operating pressure
300psi(20.68bar)
pH Range
2-11
Maximum feed water SDI15
5
Maximum influent turbidity /NTU
1
Free chlorine tolerance(mg/L)
0.1
- 4. Notice
(1) The first 5 gallons of produced water must be discarded. This initial stage of produced water is not drinkable, nor can it be used as cooking water.
(2) After the initial wetting, the components need to be kept in a wet state forever.
(3) When the system is out of service for a long time, it is recommended to immerse the membrane element in the preservation solution to prevent the growth of microorganisms in the system. Before using again, wash off the preservation solution.
(4) The membrane element still has some tolerance for short-term exposure to chlorine (hypochlorite). However, continuous contact may cause damage to the membrane element, so the above situation should be avoided.
From the supplier
TW-3012-600
- TestingCondition and Performance
Model
Pressure
psi(bar)
Permeate Flow
GPD(L/H)
Stable Rejection
(%)
TW-3012-600
100(6.9)
600(94.64)
96
- The flow and rejection are based on following testing condition: 500ppm softened tap water、temperature 25°C、pH7.5-8、recovery rate 35%and above testing pressure
- The minimum rejection is 95.0%。
- One single membrane flow may fluctuate within±20%
- Membrane Size
Model
inch(mm)
A
B
C
D
E
TW-3012-600
11.74
(298)
0.875
(21±0.5)
0.68
(17)
2.91
(74±1)
10
(254)
- 3.Operation Limits and Condition
Operation Limits
Membrane type
Polyamide composite membrane
Maximum feed water temperature
45℃
Maximum operating pressure
300psi(20.68bar)
pH Range
2-11
Maximum feed water SDI15
5
Maximum influent turbidity /NTU
1
Free chlorine tolerance(mg/L)
0.1
- 4. Notice
(1) The first 5 gallons of produced water must be discarded. This initial stage of produced water is not drinkable, nor can it be used as cooking water.
(2) After the initial wetting, the components need to be kept in a wet state forever.
(3) When the system is out of service for a long time, it is recommended to immerse the membrane element in the preservation solution to prevent the growth of microorganisms in the system. Before using again, wash off the preservation solution.
(4) The membrane element still has some tolerance for short-term exposure to chlorine (hypochlorite). However, continuous contact may cause damage to the membrane element, so the above situation should be avoided.
About the supplier
Main products: Small household appliances, Cleaning Household Appliances
- ✓Exhibited at 9 of the last 10 Canton Fairs
- ✓Industry and Trade Company
- ✓Founded 1996
- Exhibited at 9 of the last 10 Canton Fairs
- Industry and Trade Company
- Founded 1996