0.6/1kV copper conductor XLPE insulated PVC sheathed power cable
HENAN TONG-DA CABLE CO.,LTD
The supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied

0.6/1kV copper conductor XLPE insulated PVC sheathed power cable
HENAN TONG-DA CABLE CO.,LTDThe supplier hasn’t listed a price. We can get their current prices and MOQ.
Verify from $29 · written report in 3 business days · 100% refund if not satisfied
About this product
- Materials: copper
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
- Made in: Henan, China
About this product
- Materials: copper
- Exports to: Mainland China, Africa, Middle East, Southeast Asia, South Asia, Central Asia, USA and Canada, Latin America, Russia, EU, Other European Countries, Japan and South Korea, Hong Kong China, Macao China and Taiwan China, Others
- Made in: Henan, China
Product details
| Materials | copper |
|---|
Product details
| Materials | copper |
|---|
From the supplier
YJV/YJLV-0.6/1-kV-Single-Core
Application:
This product is suitable for ac 50HZ, it can be used in line with rated voltage of 0.6/1kv power transmission and distribution. unable to bear external mech-anical force and pressure.
Construction :
- 1) Conductor : Copper or aluminum ,Class 1 or Class 2,solid or stranded conductors
- 2) Insulation: Cross-linked polyethylene XLPE
- 3) Over sheath:Polyvinyl chloride PVC
SPECIFICATIONS:
IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1:Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV) .
YJV/YJLV-0.6-1-kV-Multi-Core
Application:
This product is suitable for ac 50HZ, it can be used in line with rated voltage of 0.6/1kv power transmission and distribution. unable to bear external mech-anical force and pressure.
Construction :
- 1) Conductor : Copper or aluminum ,Class 1 or Class 2,solid or stranded conductors
- 2) Insulation: Cross-linked polyethylene XLPE
- 3) Filler:Non-hygroscopic material
- 4) Binder tape:Non-hygroscopic material
- 5) Oversheath:Polyvinyl chloride PVC
SPECIFICATIONS:
IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1:Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)
0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)1X1.50.7 1.4 5.5 4812.123321X2.50.7 1.4 5.9 597.4131421X40.7 1.4 6.4 754.6141551X60.7 1.4 6.9 953.0852691X100.7 1.4 8.0 1401.8371921X160.7 1.4 9.0 2001.15921151X250.9 1.4 10.6 3100.7271201501X350.9 1.4 11.6 4100.5241501801X501.0 1.4 13.1 5100.3871802151X701.1 1.4 15.0 7100.2682302651X951.1 1.5 16.8 9900.1932853201X1201.2 1.5 18.4 12300.1533353601X1501.4 1.6 20.5 14500.1243854101X1851.6 1.6 22.6 18000.09914504601X2401.7 1.7 25.2 23000.07545355351x3001.8 1.8 27.8 29600.06016206051x4002.0 1.9 31.4 38000.0470 7206851x5002.2 2.0 34.9 48000.03668357751X6302.4 2.2 39.1 61000.02839608650.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)2X1.50.7 1.8 10.4 10512.124352X2.50.7 1.8 11.2 1357.4133462X40.7 1.8 12.2 1754.6143592X60.7 1.8 13.2 2303.0855752X100.7 1.8 15.4 3401.83761002X160.7 1.8 17.4 4801.15971302X250.9 1.8 20.5 7000.7271301652X350.9 1.8 22.5 9300.5241602002X501.0 1.8 20.3 10000.3871952402X701.1 1.8 23.3 14000.2682452902X951.1 1.9 26.2 19500.1933053552X1201.2 2.0 29.4 24500.1533554052X1501.4 2.2 32.6 30000.1244054502X1851.6 2.3 36.0 37000.09914655100.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X1.50.7 1.8 11.8 13512.121303X2.50.7 1.8 12.7 1807.4128393X40.7 1.8 13.8 2254.6137513X60.7 1.8 14.9 3003.0847643X100.7 1.8 17.2 4301.8365863X160.7 1.8 19.4 6301.15841103X250.9 1.8 22.8 9400.7271101403X350.9 1.8 25.0 12500.5241351703X501.0 1.8 24.4 15000.3871702053X701.1 1.9 29.4 21400.2682152503X951.1 2.0 33.6 29600.1932653003X1201.2 2.1 35.9 37600.1533103453X1501.4 2.3 39.9 44200.1243503853X1851.6 2.4 44.1 59500.09914054353X2401.7 2.6 51.1 71000.07544805003X3001.8 2.7 56.1 90000.06015555653X4002.0 3.0 62.4 100000.0470 6406400.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)4X1.50.7 1.8 12.6 16012.121304X2.50.7 1.8 13.6 2107.4128394X40.7 1.8 14.8 2804.6137514X60.7 1.8 16.0 3803.0847644X100.7 1.8 18.6 5301.8365864X160.7 1.8 21.0 8001.15841104X250.9 1.8 24.9 12400.7271101404X350.9 1.8 28.3 16000.5241351704X501.0 1.8 28.4 20000.3871702054X701.1 2.033.1 28000.2682152504X951.1 2.137.1 40000.1932653004X1201.2 2.240.8 50000.1533103454X1501.4 2.445.2 61000.1243503854X1851.6 2.652.1 76000.09914054354X2401.7 2.857.8 95000.07544805004X3001.8 3.063.5 120000.06015555654X4002.0 3.370.9 160000.0470 6406400.6/1kV-5 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)5X1.50.7 1.8 11.7 17012.121305X2.50.7 1.8 12.8 2507.4128395X40.7 1.8 14.0 3304.6137515X60.7 1.8 15.4 4603.0847645X100.7 1.8 18.8 7001.8365865X160.7 1.8 21.8 10001.15841105X250.9 1.8 26.2 15400.7271101405X350.9 1.8 28.0 20800.5241351705X501.0 1.9 32.4 27600.3871702055X701.1 2.137.4 38900.2682152505X951.1 2.241.7 51200.1932653005X1201.2 2.446.2 65300.1533103455X1501.4 2.653.1 80000.1243503855X1851.6 2.858.9 98000.09914054355X2401.7 3.065.6 124000.07544805005X3001.8 3.272.0 154500.06015555650.6/1kV-3+1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X2.5+1X1.50.7/0.71.8 12.3 2007.41/12.128393X4+1X2.50.7/0.71.8 13.4 2604.61/7.4137513X6+1X40.7/0.71.8 14.6 3503.08/4.6147643X10+1X60.7/0.71.8 16.9 4801.83/3.0865863X16+1X100.7/0.71.8 19.4 7601.15/1.83841103X25+1X160.9/0.71.8 22.8 10400.727/1.151101403X35+1X160.9/0.71.8 25.1 14200.524/1.151351703X50+1X251.0/0.91.8 28.2 18300.387/0.7271702053X70+1X351.1/0.91.9 31.9 25000.268/0.5242152503X95+1X501.1/1.02.135.7 34000.193/0.3872653003X120+1X701.2/1.12.239.6 43000.153/0.2683103453X150+1X701.4/1.12.343.6 52000.124/0.2683503853X185+1X951.6/1.12.549.8 65000.0991/0.1934054353X240+1X1201.7/1.22.755.3 85000.0754/0.1534805003X300+1X1501.8/1.42.957.0 100000.0601/0.1245555653X400+1X1852.0/1.73.170.0 133000.0470/0.09916406400.6/1kV-4+1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)4X2.5+1X1.50.7/0.71.8 13.2 2207.41/12.128394X4+1X2.50.7/0.71.8 14.5 3204.61/7.4137514X6+1X40.7/0.71.8 15.9 4203.08/4.6147644X10+1X60.7/0.71.8 18.5 6501.83/3.0865864X16+1X100.7/0.71.8 21.3 9501.15/1.83841104X25+1X160.9/0.71.8 25.7 14500.727/1.151101404X35+1X160.9/0.71.8 28.2 18500.524/1.151351704X50+1X251.0/0.91.9 28.9 25000.387/0.7271702057X70+1X351.1/0.92.0 32.2 34500.268/0.5242152504X95+1X501.1/1.02.236.9 47000.193/0.3872653004X120+1X701.2/1.12.340.8 60000.153/0.2683103454X150+1X701.4/1.12.544.7 71000.124/0.2683503854X185+1X951.6/1.12.750.7 90000.0991/0.1934054354X240+1X1201.7/1.22.956.4 104000.0754/0.1534805004X300+1X1501.8/1.43.164.0 135000.0601/0.1245555650.6/1kV-3+2 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X2.5+2X1.50.7/0.71.8 13.0 2007.41/12.128393X4+2X2.50.7/0.71.8 14.3 2604.61/7.4137513X6+2X40.7/0.71.8 15.6 3503.08/4.6147643X10+2X60.7/0.71.8 17.9 4801.83/3.0865863X16+2X100.7/0.71.8 20.8 7601.15/1.83841103X25+2X160.9/0.71.8 25.2 10400.727/1.151101403X35+2X160.9/0.71.8 26.8 14200.524/1.151351703X50+2X251.0/0.91.9 28.7 18300.387/0.7271702053X70+2X351.1/0.92.0 32.2 25000.268/0.5242152503X95+2X501.1/1.02.236.7 34000.193/0.3872653003X120+2X701.2/1.12.340.8 43000.153/0.2683103453X150+2X701.4/1.12.444.5 52000.124/0.2683503853X185+2X951.6/1.12.650.5 65000.0991/0.1934054353X240+2X1201.7/1.22.856.1 85000.0754/0.1534805003X300+2X1501.8/1.43.063.7 100000.0601/0.124555565
From the supplier
YJV/YJLV-0.6/1-kV-Single-Core
Application:
This product is suitable for ac 50HZ, it can be used in line with rated voltage of 0.6/1kv power transmission and distribution. unable to bear external mech-anical force and pressure.
Construction :
- 1) Conductor : Copper or aluminum ,Class 1 or Class 2,solid or stranded conductors
- 2) Insulation: Cross-linked polyethylene XLPE
- 3) Over sheath:Polyvinyl chloride PVC
SPECIFICATIONS:
IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1:Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV) .
YJV/YJLV-0.6-1-kV-Multi-Core
Application:
This product is suitable for ac 50HZ, it can be used in line with rated voltage of 0.6/1kv power transmission and distribution. unable to bear external mech-anical force and pressure.
Construction :
- 1) Conductor : Copper or aluminum ,Class 1 or Class 2,solid or stranded conductors
- 2) Insulation: Cross-linked polyethylene XLPE
- 3) Filler:Non-hygroscopic material
- 4) Binder tape:Non-hygroscopic material
- 5) Oversheath:Polyvinyl chloride PVC
SPECIFICATIONS:
IEC 60228 Conductors of insulate cables
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1:Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)
0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)1X1.50.7 1.4 5.5 4812.123321X2.50.7 1.4 5.9 597.4131421X40.7 1.4 6.4 754.6141551X60.7 1.4 6.9 953.0852691X100.7 1.4 8.0 1401.8371921X160.7 1.4 9.0 2001.15921151X250.9 1.4 10.6 3100.7271201501X350.9 1.4 11.6 4100.5241501801X501.0 1.4 13.1 5100.3871802151X701.1 1.4 15.0 7100.2682302651X951.1 1.5 16.8 9900.1932853201X1201.2 1.5 18.4 12300.1533353601X1501.4 1.6 20.5 14500.1243854101X1851.6 1.6 22.6 18000.09914504601X2401.7 1.7 25.2 23000.07545355351x3001.8 1.8 27.8 29600.06016206051x4002.0 1.9 31.4 38000.0470 7206851x5002.2 2.0 34.9 48000.03668357751X6302.4 2.2 39.1 61000.02839608650.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)2X1.50.7 1.8 10.4 10512.124352X2.50.7 1.8 11.2 1357.4133462X40.7 1.8 12.2 1754.6143592X60.7 1.8 13.2 2303.0855752X100.7 1.8 15.4 3401.83761002X160.7 1.8 17.4 4801.15971302X250.9 1.8 20.5 7000.7271301652X350.9 1.8 22.5 9300.5241602002X501.0 1.8 20.3 10000.3871952402X701.1 1.8 23.3 14000.2682452902X951.1 1.9 26.2 19500.1933053552X1201.2 2.0 29.4 24500.1533554052X1501.4 2.2 32.6 30000.1244054502X1851.6 2.3 36.0 37000.09914655100.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X1.50.7 1.8 11.8 13512.121303X2.50.7 1.8 12.7 1807.4128393X40.7 1.8 13.8 2254.6137513X60.7 1.8 14.9 3003.0847643X100.7 1.8 17.2 4301.8365863X160.7 1.8 19.4 6301.15841103X250.9 1.8 22.8 9400.7271101403X350.9 1.8 25.0 12500.5241351703X501.0 1.8 24.4 15000.3871702053X701.1 1.9 29.4 21400.2682152503X951.1 2.0 33.6 29600.1932653003X1201.2 2.1 35.9 37600.1533103453X1501.4 2.3 39.9 44200.1243503853X1851.6 2.4 44.1 59500.09914054353X2401.7 2.6 51.1 71000.07544805003X3001.8 2.7 56.1 90000.06015555653X4002.0 3.0 62.4 100000.0470 6406400.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)4X1.50.7 1.8 12.6 16012.121304X2.50.7 1.8 13.6 2107.4128394X40.7 1.8 14.8 2804.6137514X60.7 1.8 16.0 3803.0847644X100.7 1.8 18.6 5301.8365864X160.7 1.8 21.0 8001.15841104X250.9 1.8 24.9 12400.7271101404X350.9 1.8 28.3 16000.5241351704X501.0 1.8 28.4 20000.3871702054X701.1 2.033.1 28000.2682152504X951.1 2.137.1 40000.1932653004X1201.2 2.240.8 50000.1533103454X1501.4 2.445.2 61000.1243503854X1851.6 2.652.1 76000.09914054354X2401.7 2.857.8 95000.07544805004X3001.8 3.063.5 120000.06015555654X4002.0 3.370.9 160000.0470 6406400.6/1kV-5 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)5X1.50.7 1.8 11.7 17012.121305X2.50.7 1.8 12.8 2507.4128395X40.7 1.8 14.0 3304.6137515X60.7 1.8 15.4 4603.0847645X100.7 1.8 18.8 7001.8365865X160.7 1.8 21.8 10001.15841105X250.9 1.8 26.2 15400.7271101405X350.9 1.8 28.0 20800.5241351705X501.0 1.9 32.4 27600.3871702055X701.1 2.137.4 38900.2682152505X951.1 2.241.7 51200.1932653005X1201.2 2.446.2 65300.1533103455X1501.4 2.653.1 80000.1243503855X1851.6 2.858.9 98000.09914054355X2401.7 3.065.6 124000.07544805005X3001.8 3.272.0 154500.06015555650.6/1kV-3+1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X2.5+1X1.50.7/0.71.8 12.3 2007.41/12.128393X4+1X2.50.7/0.71.8 13.4 2604.61/7.4137513X6+1X40.7/0.71.8 14.6 3503.08/4.6147643X10+1X60.7/0.71.8 16.9 4801.83/3.0865863X16+1X100.7/0.71.8 19.4 7601.15/1.83841103X25+1X160.9/0.71.8 22.8 10400.727/1.151101403X35+1X160.9/0.71.8 25.1 14200.524/1.151351703X50+1X251.0/0.91.8 28.2 18300.387/0.7271702053X70+1X351.1/0.91.9 31.9 25000.268/0.5242152503X95+1X501.1/1.02.135.7 34000.193/0.3872653003X120+1X701.2/1.12.239.6 43000.153/0.2683103453X150+1X701.4/1.12.343.6 52000.124/0.2683503853X185+1X951.6/1.12.549.8 65000.0991/0.1934054353X240+1X1201.7/1.22.755.3 85000.0754/0.1534805003X300+1X1501.8/1.42.957.0 100000.0601/0.1245555653X400+1X1852.0/1.73.170.0 133000.0470/0.09916406400.6/1kV-4+1 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)4X2.5+1X1.50.7/0.71.8 13.2 2207.41/12.128394X4+1X2.50.7/0.71.8 14.5 3204.61/7.4137514X6+1X40.7/0.71.8 15.9 4203.08/4.6147644X10+1X60.7/0.71.8 18.5 6501.83/3.0865864X16+1X100.7/0.71.8 21.3 9501.15/1.83841104X25+1X160.9/0.71.8 25.7 14500.727/1.151101404X35+1X160.9/0.71.8 28.2 18500.524/1.151351704X50+1X251.0/0.91.9 28.9 25000.387/0.7271702057X70+1X351.1/0.92.0 32.2 34500.268/0.5242152504X95+1X501.1/1.02.236.9 47000.193/0.3872653004X120+1X701.2/1.12.340.8 60000.153/0.2683103454X150+1X701.4/1.12.544.7 71000.124/0.2683503854X185+1X951.6/1.12.750.7 90000.0991/0.1934054354X240+1X1201.7/1.22.956.4 104000.0754/0.1534805004X300+1X1501.8/1.43.164.0 135000.0601/0.1245555650.6/1kV-3+2 core copper conductor XLPE insulated PVC sheathed power cableNo. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)3X2.5+2X1.50.7/0.71.8 13.0 2007.41/12.128393X4+2X2.50.7/0.71.8 14.3 2604.61/7.4137513X6+2X40.7/0.71.8 15.6 3503.08/4.6147643X10+2X60.7/0.71.8 17.9 4801.83/3.0865863X16+2X100.7/0.71.8 20.8 7601.15/1.83841103X25+2X160.9/0.71.8 25.2 10400.727/1.151101403X35+2X160.9/0.71.8 26.8 14200.524/1.151351703X50+2X251.0/0.91.9 28.7 18300.387/0.7271702053X70+2X351.1/0.92.0 32.2 25000.268/0.5242152503X95+2X501.1/1.02.236.7 34000.193/0.3872653003X120+2X701.2/1.12.340.8 43000.153/0.2683103453X150+2X701.4/1.12.444.5 52000.124/0.2683503853X185+2X951.6/1.12.650.5 65000.0991/0.1934054353X240+2X1201.7/1.22.856.1 85000.0754/0.1534805003X300+2X1501.8/1.43.063.7 100000.0601/0.124555565
About the supplier
Main products: Cables, Household cable, Coaxial cable, Wires, Cable
- ✓Exhibited at 10 of the last 10 Canton Fairs
- ✓Manufacturer
- ✓Founded 2002
- ✓Canton Fair Premium Supplier
- ✓National high-tech enterprise
- ✓1 certificate on file
Light & Electrical exhibitors show in Phase 1 of the Canton Fair, 15 to 19 October 2026.
- Exhibited at 10 of the last 10 Canton Fairs
- Manufacturer
- Founded 2002
- Canton Fair Premium Supplier